hardware:confusa
This is an old revision of the document!
Table of Contents
confusa{01..14}
Summary
We have 14 confusa systems donated by Ampere. They are ARM64 Jenkins builders in the upstream jenkins.ceph.com.
Racking Ticket: https://redhat.service-now.com/surl.do?n=PNT0805570
Hardware Specs
| Count | Manufacturer | Model | Capacity | Notes | |
|---|---|---|---|---|---|
| Chassis | N/A | Lenovo | HR330A 7X33CTO1WW | N/A | |
| Mainboard | N/A | Lenovo | FALCON | N/A | |
| CPU | 1 | Ampere | eMAG® Processor ARMv8 @ 3000 MHz | 32 cores total | |
| RAM | 8 DIMMs | Samsung | M393A2K43CB2-CTD | 16GB | 128GB total |
| SSD | 1 | Micron | Micron_5200_MTFDDAK480TDC | 480GB | |
| NIC | 1 ports | Intel | I210 | 1Gb | Port 1 cabled as uplink |
| Infiniband | 2 ports | Mellanox | 01GR252 | 25Gb | Unused |
Setting up as Jenkins agents
- Reimage using Cobbler
- Once the OS install is done,
- Run the ceph-cm-ansible
usersrole - Run
ansible-playbook common.yml --tags vars,nagios,monitoring-scripts --limit confusa##
BMC/OOB Access
Please note that the ipmi password is a bit different here because of password rules in the BMC -
inktank/ApGNXcA7!
I have only ever been able to remotely control these using the “Java SOL” in the BMC's Web GUI. “Console Redirection” option in the Web UI also doesn't appear to work.
To use ipmi sol activate, you must first set the baud rate to 115.2k:
ipmi <host> sol set non-volatile-baud-rate 115.2
ipmi <host> sol set non-volatile-baud-rate 115.2
hardware/confusa.1686210527.txt.gz · Last modified: by dmick