This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
hardware:confusa [2023/05/19 16:05] zmc slaves->agents |
hardware:confusa [2024/01/25 00:44] (current) dmick [BMC/OOB Access] |
||
---|---|---|---|
Line 27: | Line 27: | ||
===== BMC/OOB Access ===== | ===== BMC/OOB Access ===== | ||
- | Please note that the ipmi password is a bit different here because of password rules in the BMC - | + | Please note that the ipmi password is a bit different here because of password rules in the BMC (note the trailing '!'): |
inktank/ApGNXcA7! | inktank/ApGNXcA7! | ||
| | ||
- | I have only ever been able to remotely control these using the "Java SOL" in the BMC's Web GUI. ''ipmitool sol activate'' is using the wrong baudrate and "Console Redirection" option in the Web UI also doesn't appear to work. | + | "Console Redirection" option in the BMC Web GUI doesn't appear to work. |
+ | |||
+ | To use ''ipmi sol activate'', you must first set the baud rate to 115.2k: | ||
+ | |||
+ | ''ipmi <host> sol set volatile-baud-rate 115.2'' | ||
+ | |||
+ | ''ipmi <host> sol set non-volatile-baud-rate 115.2'' |