hardware:confusa [2023/05/19 16:05]
zmc slaves->agents
hardware:confusa [2024/01/25 00:43]
dmick [BMC/OOB Access]
Line 30: Line 30:
     inktank/​ApGNXcA7!     inktank/​ApGNXcA7!
     ​     ​
-I have only ever been able to remotely control these using the "Java SOL" in the BMC'​s ​Web GUI.  ''​ipmitool ​sol activate'' ​is using the wrong baudrate and "​Console Redirection"​ option in the Web UI also doesn'​t appear ​to work.+ "Console Redirection" ​option ​in the BMC Web GUI doesn'​t appear to work.  ​ 
 + 
 +To use ''​ipmi sol activate''​, you must first set the baud rate to 115.2k: 
 + 
 +''​ipmi <​host>​ sol set volatile-baud-rate 115.2''​ 
 + 
 +''​ipmi <​host>​ sol set non-volatile-baud-rate 115.2''​