This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| 
                    hardware:confusa [2021/06/30 15:10] djgalloway [Summary]  | 
                
                    hardware:confusa [2024/01/25 00:44] (current) dmick [BMC/OOB Access]  | 
            ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| ===== Summary ===== | ===== Summary ===== | ||
| - | We have 14 confusa systems. They are ARM64 Jenkins builders in the upstream [[production:jenkins.ceph.com]]. | + | We have 14 confusa systems donated by Ampere. They are ARM64 Jenkins builders in the upstream [[production:jenkins.ceph.com]]. | 
| + | |||
| + | **Racking Ticket:** https://redhat.service-now.com/surl.do?n=PNT0805570 | ||
| ===== Hardware Specs ===== | ===== Hardware Specs ===== | ||
| Line 16: | Line 18: | ||
| ^ Infiniband | 2 ports | Mellanox  | 01GR252  | 25Gb | Unused  | | ^ Infiniband | 2 ports | Mellanox  | 01GR252  | 25Gb | Unused  | | ||
| - | ===== Setting up as Jenkins slaves ===== | + | ===== Setting up as Jenkins agents ===== | 
| - Reimage using Cobbler | - Reimage using Cobbler | ||
| - Once the OS install is done, | - Once the OS install is done, | ||
| Line 23: | Line 25: | ||
| - Run https://github.com/ceph/ceph-build/blob/master/ansible/examples/slave_static.yml | - Run https://github.com/ceph/ceph-build/blob/master/ansible/examples/slave_static.yml | ||
| - | Please note that the ipmi password is a bit different here because of password roles in the ipmi - | + | ===== BMC/OOB Access ===== | 
| + | |||
| + | Please note that the ipmi password is a bit different here because of password rules in the BMC (note the trailing '!'): | ||
| inktank/ApGNXcA7! | inktank/ApGNXcA7! | ||
| + |  | ||
| + | "Console Redirection" option in the BMC Web GUI doesn't appear to work.  | ||
| + | |||
| + | To use ''ipmi sol activate'', you must first set the baud rate to 115.2k: | ||
| + | |||
| + | ''ipmi <host> sol set volatile-baud-rate 115.2'' | ||
| + | |||
| + | ''ipmi <host> sol set non-volatile-baud-rate 115.2'' | ||