User Tools

Site Tools


hardware:confusa

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
hardware:confusa [2021/01/21 17:19] – [Hardware Specs] akraitmanhardware:confusa [2026/08/19 19:13] (current) – djgalloway
Line 3: Line 3:
  
 ===== Summary ===== ===== Summary =====
-We have 14 confusa systems. Jenkins slaves in the upstream jenkins.+We have 14 confusa systems donated by Ampere. They are ARM64 Jenkins builders in the upstream [[production:jenkins.ceph.com]]. 
 + 
 +**Racking Ticket:** https://redhat.service-now.com/surl.do?n=PNT0805570 
 + 
 +2026 Note: These did migrate from Red Hat to IBM.  I think they'd be good to use as teuthology testnodes to run ARM64 integration tests.
  
 ===== Hardware Specs ===== ===== Hardware Specs =====
Line 16: Line 20:
 ^ Infiniband | 2 ports  | Mellanox           | 01GR252                                     | 25Gb            | Unused                                                                                                         | ^ Infiniband | 2 ports  | Mellanox           | 01GR252                                     | 25Gb            | Unused                                                                                                         |
  
-===== Setting up as Jenkins slaves =====+===== Setting up as Jenkins agents =====
   - Reimage using Cobbler   - Reimage using Cobbler
   - Once the OS install is done,   - Once the OS install is done,
Line 22: Line 26:
     - Run ''%%ansible-playbook common.yml --tags vars,nagios,monitoring-scripts --limit confusa##%%''     - Run ''%%ansible-playbook common.yml --tags vars,nagios,monitoring-scripts --limit confusa##%%''
     - Run https://github.com/ceph/ceph-build/blob/master/ansible/examples/slave_static.yml     - Run https://github.com/ceph/ceph-build/blob/master/ansible/examples/slave_static.yml
 +
 +===== BMC/OOB Access =====
 +
 +Please note that the ipmi password is a bit different here because of password rules in the BMC (note the trailing '!'):
 +    inktank/ApGNXcA7!
 +    
 + "Console Redirection" option in the BMC Web GUI doesn't appear to work.  
 +
 +To use ''ipmi sol activate'', you must first set the baud rate to 115.2k:
 +
 +''ipmi <host> sol set volatile-baud-rate 115.2''
 +
 +''ipmi <host> sol set non-volatile-baud-rate 115.2''
hardware/confusa.1611249585.txt.gz · Last modified: by akraitman