User Tools

Site Tools


hardware:confusa

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
hardware:confusa [2021/03/07 12:46]
akraitman [Setting up as Jenkins slaves]
hardware:confusa [2024/01/25 00:43]
dmick [BMC/OOB Access]
Line 3: Line 3:
  
 ===== Summary ===== ===== Summary =====
-We have 14 confusa systems. Jenkins ​slaves ​in the upstream jenkins.+We have 14 confusa systems ​donated by AmpereThey are ARM64 Jenkins ​builders ​in the upstream ​[[production:​jenkins.ceph.com]]. 
 + 
 +**Racking Ticket:** https://​redhat.service-now.com/​surl.do?​n=PNT0805570
  
 ===== Hardware Specs ===== ===== Hardware Specs =====
Line 16: Line 18:
 ^ Infiniband | 2 ports  | Mellanox ​          | 01GR252 ​                                    | 25Gb            | Unused ​                                                                                                        | ^ Infiniband | 2 ports  | Mellanox ​          | 01GR252 ​                                    | 25Gb            | Unused ​                                                                                                        |
  
-===== Setting up as Jenkins ​slaves ​=====+===== Setting up as Jenkins ​agents ​=====
   - Reimage using Cobbler   - Reimage using Cobbler
   - Once the OS install is done,   - Once the OS install is done,
Line 23: Line 25:
     - Run https://​github.com/​ceph/​ceph-build/​blob/​master/​ansible/​examples/​slave_static.yml     - Run https://​github.com/​ceph/​ceph-build/​blob/​master/​ansible/​examples/​slave_static.yml
  
-Please note that the ipmi password is a bit different here because of password ​roles in the ipmi -+===== BMC/OOB Access ===== 
 + 
 +Please note that the ipmi password is a bit different here because of password ​rules in the BMC -
     inktank/​ApGNXcA7!     inktank/​ApGNXcA7!
 +    ​
 + "​Console Redirection"​ option in the BMC Web GUI doesn'​t appear to work.  ​
 +
 +To use ''​ipmi sol activate'',​ you must first set the baud rate to 115.2k:
 +
 +''​ipmi <​host>​ sol set volatile-baud-rate 115.2''​
 +
 +''​ipmi <​host>​ sol set non-volatile-baud-rate 115.2''​
hardware/confusa.txt · Last modified: 2024/01/25 00:44 by dmick